Technical parameters p>
Rated power: 160kW 200kw 250kw p>
Rated frequency: 4000Hz p>
Maxiumtemperature: 1600°C,2400°C P>
High temperature zone volume: ¢ 450 & Times; 900mm p>
Operators working atmosphere: hydrogen, nitrogen, argon, inert gas, etc. P>
Temperature uniform value: <& plusmn; 12°C P>
Temperature range: 200-2200°C, 800-2400°C P>
Temperature measurement: infrared optical measurement P>
temperature control accuracy: & plusmn; 1°C P>
limit temperature rise speed: 400°C / min